American Journal of Ophthalmology
Volume 139, Issue 1 , Pages 18-29, January 2005

Evaluation of image artifact produced by optical coherence tomography of retinal pathology

  • Robin Ray, BS

      Affiliations

    • Department of Ophthalmology, Duke University Eye Center, Durham, North Carolina, USA
  • ,
  • Sandra S. Stinnett, DrPH

      Affiliations

    • Department of Ophthalmology, Duke University Eye Center, Durham, North Carolina, USA
  • ,
  • Glenn J. Jaffe, MD

      Affiliations

    • Department of Ophthalmology, Duke University Eye Center, Durham, North Carolina, USA
    • Corresponding Author InformationInquiries to Glenn J. Jaffe, MD, Department of Ophthalmology, Duke University Eye Center, Durham, NC 27710; fax: (919) 681-6474

Accepted 26 July 2004. published online 01 December 2004.

Purpose

To determine the frequency and type of optical coherence tomography (OCT) fast macular thickness map (FMTM) scan artifacts, and whether these artifacts depend on patient diagnosis, demographics, and ocular therapy.

Design

Retrospective observational case series.

Methods

Records from patients who underwent an ophthalmologic evaluation by a member of the Duke University Eye Center vitreoretinal faculty and had an OCT scan produced by the FMTM protocol between July 7, 2003 and July 31, 2003 were reviewed. The relationships between OCT scan artifacts and ocular diagnosis, ocular treatment, and patient demographics were determined. Logistic regression was used to relate OCT scan artifacts simultaneously with ocular diagnosis and treatment.

Results

Scans from 171 eyes were analyzed. Retinal scan artifacts, though not observed in normal eyes, were identified frequently in eyes with macular pathology (P = .049). Artifacts were observed in 43.2% of all scans, and of these, an erroneous retinal thickness measurement was obtained in 62.2%. Six types of OCT surface map artifacts were observed. Of these, inner and outer retinal misidentification, degraded image artifact, and “off center” artifact were significantly associated with central thickness calculation errors (P < .001). Neovascular age-related macular degeneration (AMD), full-thickness macular hole, and photodynamic therapy were all associated with increased artifact (P = .002, .022, and <.001, respectively).

Conclusion

Optical coherence tomography scan artifacts are seen surprisingly frequently, adversely affect retinal thickness measurements in a high proportion of cases, and are diagnosis-dependent. Recognition of these artifacts will improve retinal thickness measurement accuracy, and will prevent faulty treatment decisions that are based on inaccurate retinal thickness measurements.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This study was supported in part from an unrestricted grant from Research to Prevent Blindness, Inc. and by a Clinical Research Development Award EY11725 from the National Eye Institute (S.S.S.).

PII: S0002-9394(04)00938-9

doi:10.1016/j.ajo.2004.07.050

American Journal of Ophthalmology
Volume 139, Issue 1 , Pages 18-29, January 2005