- Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem . Ophthalmology . 2001;108:505–518
- . Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule . J Cataract Refract Surg . 1999;25:521–526
- . Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification . J Cataract Refract Surg . 2003;29:348–353
- . Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens . Ophthalmic Surg Lasers . 1998;29:587–594
- . Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges . J Cataract Refract Surg . 2000;26:1543–1549
- . Two year results: sharp versus rounded optic edges on silicone lenses . J Cataract Refract Surg . 2000;26:566–570
- Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification . J Cataract Refract Surg . 2004;30:1661–1667
- Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification . J Cataract Refract Surg . 2005;31:954–961
- . Migration of lens epithelial cells through haptic root of single-piece acrylic-foldable intraocular lens . Am J Ophthalmol . 2004;137:377–379
- Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge . J Cataract Refract Surg . 2004;30:2403–2409
- Posterior capsule opacification in rabbit eyes implanted with one-piece and three-piece hydrophobic acrylic intraocular lenses . J Cataract Refract Surg . 2005;31:805–811
- . In vivo digital imaging of the square-edged barrier effect of a silicone intraocular lens . J Cataract Refract Surg . 2004;30:2574–2584
- . A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses . Am J Ophthalmol . 2003;136:614–619
- Nd:YAG capsulotomy rates after use of the AcrySof acrylic three-piece and one-piece intraocular lenses . Br J Ophthalmol . 2005;89:1453–1457
- Update on fixation of rigid and foldable posterior chamber intraocular lenses: part 2—choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification . Ophthalmology . 1999;106:891–900
- Surgical prevention of posterior capsule opacification: part 3—Intraocular lens optic barrier effect as a second line of defense . J Cataract Refract Surg . 2000;26:198–213
- . Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification . J Cataract Refract Surg . 2001;27:608–613
Supported in part by an unrestricted grant from Advanced Medical Optics Inc.