American Journal of Ophthalmology
Volume 142, Issue 5 , Pages 750-756.e3, November 2006

Wavefront Analysis and Contrast Sensitivity of Aspheric and Spherical Intraocular Lenses: A Randomized Prospective Study

Ophthalmology Department, Federal University of Sao Paulo, Sao Paulo, Brazil.

Accepted 8 June 2006. published online 20 July 2006.

Purpose

To compare visual performance, total and high order wavefront aberrations (coma, spherical aberration, and other terms), and contrast sensitivity in 120 eyes implanted with one monofocal aspheric intraocular lens (IOL) and two spherical IOLs.

Design

Randomized prospective study.

Methods

Sixty patients were randomized to receive three IOL types: Alcon AcrySofIQ (40 eyes), AcrySofNatural (40 eyes), and advanced medical optic (AMO)Sensar (40 eyes). Complete ophthalmologic examination including uncorrected visual acuity (UCVA), best-spectacle corrected visual acuity (BSCVA), corneal topography, and wavefront analysis were performed preoperatively, 30 days, and 90 days postoperatively. Pelli-Robson chart test and functional acuity contrast testing (FACT-Optec6500) were performed approximately 50 days after surgery. Statistical analyses were performed using analysis χ2, analysis of variance (ANOVA), and multiple comparisons Tukey test.

Results

After 90 days, all eyes had postoperative BSCVA ≥20/32. The AcrySofIQ IOL showed statistically significant less induction of spherical aberration (P < .001) when compared with the AMOSensar and the AcrySofNatural IOLs. The AMOSensar presented significantly less spherical aberration then the AcrySofNatural (P < .05). The AcrySofIQ also had lower values of total and high-order aberration (HOA) (P < .05) when compared with the AMOSensar and the AcrySofNatural. The mean values of trefoil 9, coma, and HOA root mean square (RMS) decreased between one and three months (P < .001, P < .001, P = .023, P < .001, respectively) in all groups. Mean Pelli-Robson contrast sensitivity values in photopic condition were similar between the groups. The AcrySofIQ showed better results in 3cpd spatial frequency in mesopic condition using FACT-Optec 6500 (P = .008), although there were no statistical differences in photopic and mesopic with glare conditions.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supplemental Material available at AJO.com.

PII: S0002-9394(06)00726-4

doi:10.1016/j.ajo.2006.06.031

American Journal of Ophthalmology
Volume 142, Issue 5 , Pages 750-756.e3, November 2006