Purpose

To evaluate the results of sutureless amniotic membrane (AM) transplantation using fibrin glue for reconstructing corneal surfaces with partial limbal stem cell deficiency (LSCD).

Design

Retrospective noncomparative interventional case series.

Methods

Eleven eyes of nine patients that had LSCD with 120 degrees to almost 360 degrees of limbal involvement underwent superficial keratectomy to remove the conjunctivalized pannus followed by AM transplantation using fibrin glue. Additional sutureless AM patch (ProKera; Bio-Tissue, Inc, Miami, Florida, USA) was used in seven patients, and mitomycin C was applied on the cornea in four eyes and during fornix reconstruction in seven eyes. The surgery was repeated in three eyes for residual pannus.

Results

During a mean follow-up of 14.2 ± 7.7 months (range, six to 26 months), all eyes maintained a smooth and stable corneal epithelial surface without recurrent erosion or persistent epithelial defect, and showed less stromal cloudiness and vascularization. Best-corrected visual acuity improved in nine eyes (81.8%). Corneal epithelialization proceeded by epithelial growth over AM (n = 4), accompanied by dissolution of AM (n = 4) or a combination of both (n = 3). No complication was noted regarding initial or repeated uses of fibrin glue.

Conclusion

AM transplantation using fibrin glue appears to be a safe and effective method of restoring a stable corneal epithelium for cases with partial LSCD. This approach avoids the need of transplanting limbal epithelial stem cells.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0002-9394(08)00039-1

doi:10.1016/j.ajo.2008.01.009

American Journal of Ophthalmology
Volume 145, Issue 5 , Pages 787-794, May 2008