« Previous
Next »
American Journal of Ophthalmology
Volume 145, Issue 5
, Pages 780-786.e1
, May 2008
Intraocular Pressure Measurements Following Descemet Stripping Endothelial Keratoplasty
References
- . Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;13:1935–1342
- . Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence. J Cataract Refract Surg. 2006;32:411–418
- . Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg. 2005;21:339–345
- . Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1–30
- . Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45:3118–3121
- . Intraocular pressure measurement—comparison of dynamic contour tonometry and Goldmann applanation tonometry. J Glaucoma. 2006;15:2–6
- . The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br J Ophthalmol. 2005;89:1572–1575
- . Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry. Eye. 2006;20:191–198
- . Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2003;44:3790–3794
- . Assessment of the PASCAL dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004;30:746–751
- Pneumotonometric versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 1999;25:1344–1348
- . Reliability of intraocular pressure measurements after myopic excimer refractive photokeratectomy. Ophthalmology. 1998;105:2193–2196
- . Dynamic contour tonometry: principal and use. Clin Exp Ophthalmol. 2006;34:837–840
- . Measuring intraocular pressure—adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol. 2006;17:115–119
- . Dynamic contour tonometry versus Goldmann applanation tonometry—a comparison of agreement and reproducibility. Graefes Arch Clin Exp Ophthalmol. 2007;245:1027–1030
- . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310
- . Comparison of dynamic contour tonometry with Goldmann applanation tonometry over a wider range of central corneal thickness. J Glaucoma. 2005;14:288–292
- Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology. 2007;114:20–26
- Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry. Ophthalmology. 2006;113:2156–2162
- Comparison of dynamic contour tonometry and Goldmann applanation in glaucoma patients and healthy subjects. Am J Ophthalmol. 2006;142:583–590
- Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol. 2005;123:1532–1537
- . Comparison of dynamic contour tonometry and Goldmann applanation tonometry in African-American subjects. Ophthalmology. 2007;114:658–665
- . Comparisons between PASCAL dynamic tonometry, the tonopen, and Goldmann applanation tonometry in patients with glaucoma. Acta Ophthalmol Scand. 2007;85:272–279
- . Dynamic contour tonometry; a comparative study on human cadaver eyes. Arch Ophthalmol. 2004;122:1287–1292
- . Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration. Graefes Arch Clin Exp Ophthalmol. 2005;243:359–366
- . Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology. 2000;107:1967–1968
- . Corneal transplant rejection rate and severity after endothelial keratoplasty. Cornea. 2007;26:1039–1042
- Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic and noncontact tonometry. Am J Ophthalmol. 2007;143:39–47
- . Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma. 2007;16:581–588
- . The influence of corneal properties on rebound tonometry. Ophthalmology. 2008;115:80–84
PII: S0002-9394(08)00040-8
doi: 10.1016/j.ajo.2008.01.010
© 2008 Elsevier Inc. All rights reserved.
« Previous
Next »
American Journal of Ophthalmology
Volume 145, Issue 5
, Pages 780-786.e1
, May 2008
