American Journal of Ophthalmology
Volume 146, Issue 1 , Pages 42-45 , July 2008

Real-Time Optical Coherence Tomography-Guided Femtosecond Laser Sub-Bowman Keratomileusis on Human Donor Eyes

  • Omid Kermani

      Affiliations

    • Augenklinik am Neumarkt, Köln, Germany
    • Corresponding Author InformationInquiries to Omid Kermani, Augenklinik am Neumarkt, Schildergasse 107-109 D-50667 Köln, Germany
  • ,
  • Will Fabian

      Affiliations

    • Rowiak GmbH, Hannover, Germany
  • ,
  • Holger Lubatschowski

      Affiliations

    • Rowiak GmbH, Hannover, Germany
    • Laser Zentrum Hannover e.V., Hannover, Germany.

,Accepted 3 March 2008.

References 

  1. Schmack I, Dawson DG, McCarey BE, Waring GO. Cohesive tensile strength of human LASIK wounds with histologic, ultrastructural, and clinical correlations. J Refract Surg. 2005;21:433–445
  2. Binder PS. Flap dimensions created with the IntraLase FS laser. J Cataract Refract Surg. 2004;30:26–32
  3. Sarayabo MA, Ignacio TS, Tran TS, Binder PS. A 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyes. J Refract Surg. 2007;23:331–337
  4. Stahl JS, Durrie DS, Schwendemann FJ, Boghossian AJ. Anterior segment OCT analysis of thin IntraLase femtosecond flaps. J Refract Surg. 2007;23:555–558
  5. Heisterkamp A, Ripken T, Mamom T, et al. Nonlinear side effects of fs-pulses inside corneal tissue during photodisruption. Appl Phys B. 2002;74:1–7
  6. Noack J, Vogel A. Laser-induced plasma formation in water at nanosecond to femtosecond time scales: Calculation of thresholds, absorption coefficients, and energy density. IEEE J Quantum Electron. 1999;35:1156–1162
  7. Vogel A, Noack J, Hüttman G, Paltauf G. Mechanism of femtosecond laser nanosurgery of cells and tissue. Appl Phys B. 2005;81:1015–1120
  8. Lubatschowski H, Maatz G, Heisterkamp A, et al. Application of ultrashort laser pulses for intrastromal refractive surgery. Graefes Arch Clin Exp Ophthalmol. 2000;238:33–39
  9. Heisterkamp A, Mamon T, Kermani O, et al. Intrastromal refractive surgery with ultra-short laser pulses: In-vivo study on the rabbit eye. Graefes Arch Clin Exp Ophthalmol. 2003;241:511–517
  10. Izatt JA, Hee MR, Swanson EA, et al. Micrometer-scale resolution imaging of the anterior eye in-vivo with optical coherence tomography. Arch Ophthalmol. 1994;112:1584–1589
  11. Huang D, Li Y, Radhakrishnan S, Chalita MR. Corneal and anterior segment optical coherence tomography. In:  Schuman JS,  Puliafito CA,  Fujimoto JG editor. Optical coherence tomography of ocular diseases. 2nd ed.. Thorofare, New Jersey: Slack Inc; 2004;p. 663–673
  12. Avila M, Li Y, Song JC, Huang D. High-speed optical coherence tomography for management after laser in situ keratomileusis. J Cataract Refract Surg. 2006;32:1836–1842
  13. Leitgeb R, Drexler W, Unterhuber A, et al. Ultra-high resolution Fourier-domain optical coherence tomography. Opt Express. 2004;12:2156–2165

PII: S0002-9394(08)00168-2

doi: 10.1016/j.ajo.2008.03.003

American Journal of Ophthalmology
Volume 146, Issue 1 , Pages 42-45 , July 2008