American Journal of Ophthalmology
Volume 146, Issue 4 , Pages 550-553.e2 , October 2008

Long-term Staar Toric Intraocular Lens Rotational Stability

,Accepted 28 May 2008.

References 

  1. Sun XY, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology. 2000;107:1776–1781
  2. Ruhswurm I, Scholz U, Zehetmayer M, et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg. 2000;26:1022–1027
  3. Leyland M, Zinicola P, Bloom P, Lee N. Prospective evaluation of a plate haptic toric intraocular lens. Eye. 2001;15:202–205
  4. Till JS, Yoder PR, Wilcox TK, Spielman JL. Toric intraocular lens implantation: 100 consecutive cases. J Cataract Refract Surg. 2002;28:295–301
  5. Patel CK, Ormonde S, Rosen P, Bron AJ. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. Ophthalmology. 1999;106:2190–2196
  6. Terry AC, Stark WJ, Maumenee AE, Fagadau W. Neoymium-YAG laser for posterior capsulotomy. Am J Ophthalmol. 1983;96:716–720
  7. Stark WJ, Worthen D, Holladay JT, Murray G. Neodymium: YAG lasers: an FDA report. Ophthalmology. 1985;92:209–212
  8. Winslow RL, Taylor BC. Retinal complications following YAG laser capsulotomy. Ophthalmology. 1985;92:785–789
  9. Weinreb RN, Wasserstrom JP, Parker W. Neovascular glaucoma following neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1986;104:730–731
  10. Rickman-Barger L, Florine CW, Larson RS, Lindstrom RL. Retinal detachment after neodymium-YAG laser posterior capsulotomy. Am J Ophthalmol. 1989;107:531–536
  11. Fourman S, Apisson J. Late-onset elevation in intraocular pressure after neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1991;109:511–513
  12. Nguyen TM, Miller KM. Digital overlay technique for documenting toric intraocular lens axis orientation. J Cataract Refract Surg. 2000;26:1496–1504
  13. Chang DF. Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases. J Cataract Refract Surg. 2003;29:935–940
  14. Findl O, Drexler W, Menepace R. Changes in intraocular lens position after neodymium: YAG capsulotomy. J Cataract Refract Surg. 1999;25:659–662
  15. Framme C, Hoerauf H, Roider J, Laqua H. Delayed intraocular lens dislocation after neodymium: YAG capsulotomy. J Cataract Refract Surg. 1998;24:1541–1543
  16. Levy JH, Pisacano AM, Anello RD. Displacememt of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomy. J Cataract Refract Surg. 1990;16:563–566
  17. Maguire AM, Blumenkranz MS, Ward TG, Winkelman JZ. Scleral loop fixation for posteriorly dislocated intraocular lenses (Operative technique and long-term results). Arch Ophthalmol. 1991;109:1754–1758
  18. Schneiderman TE, Johnson MW, Smiddy WE, et al. Surgical management of posteriorly dislocated silicone plate haptic intraocular lenses. Am J Ophthalmol. 1997;123:629–635
  19. Akerele T, Minasian M, Little B, Jagger J. Posterior dislocation of Staar plate haptic silicone lenses following Nd:YAG capsulotomy. Eye. 1999;13:700–702
  20. Agustin AL, Miller KM. Posterior dislocation of a plate-haptic silicone intraocular lens with large fixation holes. J Cataract Refract Surg. 2000;26:1428–1429
  21. Gonzalez GA, Irvine AR. Posterior dislocation of plate-haptic silicone lenses. Arch Ophthalmol. 1996;114:775–776
  22. Shakin EP, Carty JB. Clinical management of posterior chamber intraocular lens implants dislocated in the vitreous cavity. Ophthalmic Surg Lasers. 1995;26:529–534

PII: S0002-9394(08)00426-1

doi: 10.1016/j.ajo.2008.05.040

American Journal of Ophthalmology
Volume 146, Issue 4 , Pages 550-553.e2 , October 2008