American Journal of Ophthalmology
Volume 148, Issue 3 , Pages 427-430.e1, September 2009

Iatrogenic Retinal Breaks in 25-gauge Macular Surgery

  • H. Stevie Tan

      Affiliations

    • Department of Ophthalmology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
    • Corresponding Author InformationInquiries to H. Stevie Tan, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
  • ,
  • Marco Mura

      Affiliations

    • Department of Ophthalmology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
  • ,
  • Marc D. de Smet

      Affiliations

    • Department of Ophthalmology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
    • Department of Ophthalmology, ZNA Middelheim Campus, Antwerp, Belgium

Accepted 6 April 2009. published online 25 May 2009.

Purpose

To describe the incidence and characteristics of iatrogenic retinal breaks in 25-gauge macular surgery.

Design

Retrospective, noncomparative, interventional case series.

Methods

We included 177 consecutive operations in 171 patients who underwent 25-gauge vitrectomy for idiopathic macular pucker or idiopathic macular hole. Main outcome measures were the incidence of breaks related to the sclerotomies, the incidence of breaks occurring elsewhere, the incidence of lesions suspicious for traction, the location of identified breaks, and intraoperative induction of posterior vitreous detachment (PVD).

Results

Retinal breaks occurred in 15.8% of operations. In 6.2%, breaks were related to the sclerotomies, and in 10.7%, breaks were found elsewhere. In 8.5% of eyes, only lesions suspicious for traction were detected. Breaks or suspicious lesions were treated with external cryocoagulation in a total of 24.3% of cases. A statistically significant relation between PVD induction and presence of breaks elsewhere was identified. No correlation with lens status, initial diagnosis, or preoperative refraction was found. Retinal detachment occurred in 1.7% of cases.

Conclusions

We report an incidence of retinal breaks that is higher than previously found for 20- or 25-gauge surgery. Despite the high incidence of breaks, the incidence of postoperative retinal detachment was low. A specific characteristic was the relatively high incidence of breaks elsewhere and their relation to PVD induction. Our findings underscore the importance of scrupulous full 360-degree internal search at the end of each procedure to identify and treat all breaks and suspicious lesions optimally.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0002-9394(09)00265-7

doi:10.1016/j.ajo.2009.04.002

American Journal of Ophthalmology
Volume 148, Issue 3 , Pages 427-430.e1, September 2009