« Previous
Next »
American Journal of Ophthalmology
Volume 149, Issue 2
, Pages 245-252.e2
, 1 February 2010
Ultrasound Biomicroscopic Analysis of Iris-Sutured Foldable Posterior Chamber Intraocular Lenses
References
- . Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology. Ophthalmology. 2003;110:840–859
- . Long-term follow-up of secondary flexible, open-loop, anterior chamber intraocular lenses. J Cataract Refract Surg. 2003;29:498–503
- . Secondary implantation of angle-supported anterior chamber and scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg. 1996;22:247–252
- . Results and complications of secondary intraocular lens implantation. J Cataract Refract Surg. 1993;19:64–67
- . Ten-year follow up comparing anterior and posterior chamber intraocular lens implants. Ophthalmic Surg. 1992;23:308–315
- . Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg. 2003;29:301–308
- . Incidence and management of complications of transsclerally sutured posterior chamber lenses. J Cataract Refract Surg. 1993;19:488–493
- . Implantation of scleral-sutured posterior chamber intraocular lenses during penetrating keratoplasty. J Refract Surg. 2000;16:456–458
- . Endophthalmitis after secondary intraocular lens implantation (A case-report study). Ophthalmology. 1995;102:1925–1931
- A randomized trial of intraocular lens fixation techniques with penetrating keratoplasty. Ophthalmology. 1993;100:1437–1443
- . Simplified small-incision peripheral iris fixation of an AcrySof intraocular lens in the absence of capsule support. J Cataract Refract Surg. 2003;29:1663–1667
- . Surgical technique for suture fixation of an acrylic intraocular lens in the absence of capsule support. J Cataract Refract Surg. 2003;29:1658–1662
- . Small-incision iris fixation of foldable intraocular lenses in the absence of capsule support. Ophthalmology. 2007;114:1311–1318
- . Practical application of ultrasound biomicroscopy. Can J Ophthalmol. 1995;30:225–229
- . Ultrasound biomicroscopic evaluation of the efficacy of a transillumination technique for ciliary sulcus localization in transscleral fixation of posterior chamber intraocular lenses. J Cataract Refract Surg. 2009;35:291–296
- . Ultrasound biomicroscopy comparison of ab interno and ab externo scleral fixation of posterior chamber intraocular lenses. J Cataract Refract Surg. 2009;35:881–884
- . Long-term results of out-of-the-bag intraocular lens implantation. J Cataract Refract Surg. 2000;26:266–270
- . Measured and predicted anterior chamber depth for transscleral suture-fixated posterior chamber intraocular lenses. Ophthalmic Surg. 1993;24:28–30
- . Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation. Am J Ophthalmol. 1997;124:775–780
- . Ultrasound biomicroscopy examination of intraocular lens haptic position after phacoemulsification with continuous curvilinear capsulorrhexis and extracapsular cataract extraction with linear capsulotomy. Acta Ophthalmol Scand. 1999;77:394–396
- . Posterior chamber intraocular lens implantation after capsular tear: ultrasound biomicroscopy evaluation. J Cataract Refract Surg. 2001;27:1423–1427
- . Ultrasound biomicroscopic analysis of posterior chamber intraocular lenses with transscleral sulcus suture. Ophthalmology. 2000;107:2172–2178
- . Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. Ophthalmology. 1998;105:2091–2098
- . Determination of haptic position of transsclerally fixated posterior chamber intraocular lenses by ultrasound biomicroscopy. J Cataract Refract Surg. 1993;19:573–577
- . Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation. Ophthalmology. 2003;110:1799–1806
- . Ultrasound biomicroscopy of haptic position after transscleral fixation of posterior chamber intraocular lenses. J Cataract Refract Surg. 2001;27:1418–1422
- . [Haptic position of iris-fixed posterior chamber lenses (Determination by ultrasound biomicroscopy]). Ophthalmologe. 1997;94:651–654
- . Siepser slipknot for McCannel iris-suture fixation of subluxated intraocular lenses. J Cataract Refract Surg. 2004;30:1170–1176
- . The closed chamber slipping suture technique for iris repair. Ann Ophthalmol. 1994;26:71–72
- . Long-term outcomes of combined penetrating keratoplasty with iris-sutured intraocular lens implantation. Ophthalmology. 2003;110:1017–1022
- . Iris-sutured posterior chamber intraocular lens implantation during penetrating keratoplasty. Cornea. 2004;23:18–28
- . Iris fixation of posterior chamber intraocular lenses. J Cataract Refract Surg. 2000;26:1028–1034
- Anterior chamber width measurement by high-speed optical coherence tomography. Ophthalmology. 2005;112:238–244
- . Suture-wick endophthalmitis with sutured posterior chamber intraocular lenses. J Cataract Refract Surg. 1990;16:755–756
- . Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol. 1992;113:381–389
- . Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery. Ophthalmology. 1999;106:878–882
PII: S0002-9394(09)00622-9
doi: 10.1016/j.ajo.2009.08.022
© 2010 Elsevier Inc. All rights reserved.
« Previous
Next »
American Journal of Ophthalmology
Volume 149, Issue 2
, Pages 245-252.e2
, 1 February 2010
