American Journal of Ophthalmology
Volume 149, Issue 4 , Pages 602-607.e1, April 2010

Tear Measurement in Prosthetic Eye Users with Fourier-Domain Optical Coherence Tomography

  • Sung Eun Kim
  • ,
  • Jin Sook Yoon
  • ,
  • Sang Yeul Lee

      Affiliations

    • Corresponding Author InformationInquiries to Sang Yeul Lee, Department of Ophthalmology, Yonsei University College of Medicine, No. 134 Shinchon-dong, Seodaemun-ku, 120-752 Seoul, Korea

Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea

Accepted 31 October 2009. published online 08 February 2010.

Purpose

To investigate whether Fourier-domain (FD) optical coherence tomography (OCT) can measure the tear meniscus of anophthalmic patients using prosthetic eyes and to compare the characteristics of normal and artificial eyes.

Design

Prospective, nonrandomized, observational case series.

Methods

Thirty-one patients who had undergone anophthalmic surgery in 1 eye and had been wearing artificial eyes for more than 6 months were included. Subjects with socket inflammation, contracted sockets, or other known lid disorders were excluded. Patients were asked to complete a questionnaire regarding their demographic status and dry eye symptoms before treatment, and FD OCT scanning and the Schirmer test were performed. Three images were obtained by FD OCT on each normal and anophthalmic eye, and the tear meniscus height, tear meniscus depth, and tear meniscus angle were measured with computer calipers.

Results

FD OCT was able to visualize the tear meniscus of both normal and artificial eyes. The mean tear meniscus height of artificial eyes was significantly lower than that of normal eyes (200.59 ± 79.68 μm vs 261.24 ± 86.17 μm; P < .001). Mean tear meniscus depth, tear meniscus area, and tear meniscus volume also were significantly lower in artificial eyes than in normal eyes. The dry eye symptom score showed significantly negative correlation with tear meniscus height. The Schirmer test results correlated with tear meniscus parameters in normal eyes, but not in artificial eyes.

Conclusions

FD OCT is a valuable clinical tool in the evaluation of tear meniscus height in normal and artificial eyes. In addition, tear meniscus height can be a useful clinical parameter that estimates symptoms of ocular dryness and discomfort in both normal and artificial eyes.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0002-9394(09)00811-3

doi:10.1016/j.ajo.2009.10.023

American Journal of Ophthalmology
Volume 149, Issue 4 , Pages 602-607.e1, April 2010