American Journal of Ophthalmology
Volume 149, Issue 6 , Pages 922-925.e2, June 2010

A Method to Confirm Correct Orientation of Descemet Membrane During Descemet Membrane Endothelial Keratoplasty

Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany

Accepted 5 January 2010. published online 26 March 2010.

Purpose

Descemet membrane endothelial keratoplasty is a new technique for the replacement of diseased corneal endothelium with healthy donor endothelium. During this procedure, manipulation of the donor endothelium–Descemet membrane layer within the recipient anterior chamber can be associated with loss of the correct anterior-posterior orientation. Herein, we describe a simple method to keep the correct donor orientation during transplantation by marking the edge of the endothelium–Descemet membrane layer.

Design

Interventional case series.

Methods

Donor discs were created by stripping of the endothelium–Descemet membrane layer from corneoscleral buttons. Before completion of stripping, 3 circular marks were set in an identifiable order at the edge of the donor disc. After removal of the recipient Descemet membrane, the donor graft was inserted into the anterior chamber, unfolded, and attached to the posterior corneal stroma with an air bubble. Correct anterior-posterior orientation of the graft was identified by the clockwise order of the 3 marks.

Results

The marks allowed identification of the anterior-posterior orientation of the endothelium–Descemet membrane layer after unfolding in the anterior chamber and attachment to the recipient stroma in all cases. In 4 of 25 patients, orientation was upside down after unfolding of the roll, requiring inversion of the refolded donor graft.

Conclusions

Marking the edges of the endothelium–Descemet membrane layer helps to keep the correct orientation without adverse effects on donor detachment or corneal clarity during and after Descemet membrane endothelial keratoplasty.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supplemental Material available at AJO.com.

PII: S0002-9394(10)00021-8

doi:10.1016/j.ajo.2010.01.005

American Journal of Ophthalmology
Volume 149, Issue 6 , Pages 922-925.e2, June 2010